mirror of https://github.com/OpenTTD/OpenTTD
(svn r15103) -Change: Keep industry variables 8E and 8F in sync with 93, when changing production using results 0D, 0E or 0F of callback 29 or 35.
parent
b8d2049bc4
commit
cdd3676478
|
@ -2084,6 +2084,7 @@ static void ChangeIndustryProduction(Industry *i, bool monthly)
|
|||
const IndustrySpec *indspec = GetIndustrySpec(i->type);
|
||||
bool standard = true;
|
||||
bool suppress_message = false;
|
||||
bool recalculate_multipliers = false; ///< reinitialize production_rate to match prod_level
|
||||
/* don't use smooth economy for industries using production related callbacks */
|
||||
bool smooth_economy = _settings_game.economy.smooth_economy &&
|
||||
!(HasBit(indspec->callback_flags, CBM_IND_PRODUCTION_256_TICKS) || HasBit(indspec->callback_flags, CBM_IND_PRODUCTION_CARGO_ARRIVAL)) && // production callbacks
|
||||
|
@ -2118,6 +2119,7 @@ static void ChangeIndustryProduction(Industry *i, bool monthly)
|
|||
break;
|
||||
case 0xF: // Set production to third byte of register 0x100
|
||||
i->prod_level = Clamp(GB(GetRegister(0x100), 16, 8), PRODLEVEL_MINIMUM, PRODLEVEL_MAXIMUM);
|
||||
recalculate_multipliers = true;
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
@ -2201,8 +2203,7 @@ static void ChangeIndustryProduction(Industry *i, bool monthly)
|
|||
/* Increase if needed */
|
||||
while (mul-- != 0 && i->prod_level < PRODLEVEL_MAXIMUM) {
|
||||
i->prod_level = min(i->prod_level * 2, PRODLEVEL_MAXIMUM);
|
||||
i->production_rate[0] = min(i->production_rate[0] * 2, 0xFF);
|
||||
i->production_rate[1] = min(i->production_rate[1] * 2, 0xFF);
|
||||
recalculate_multipliers = true;
|
||||
if (str == STR_NULL) str = indspec->production_up_text;
|
||||
}
|
||||
|
||||
|
@ -2212,8 +2213,7 @@ static void ChangeIndustryProduction(Industry *i, bool monthly)
|
|||
closeit = true;
|
||||
} else {
|
||||
i->prod_level = max(i->prod_level / 2, (int)PRODLEVEL_MINIMUM); // typecast to int required to please MSVC
|
||||
i->production_rate[0] = (i->production_rate[0] + 1) / 2;
|
||||
i->production_rate[1] = (i->production_rate[1] + 1) / 2;
|
||||
recalculate_multipliers = true;
|
||||
if (str == STR_NULL) str = indspec->production_down_text;
|
||||
}
|
||||
}
|
||||
|
@ -2224,9 +2224,17 @@ static void ChangeIndustryProduction(Industry *i, bool monthly)
|
|||
closeit = true;
|
||||
} else {
|
||||
i->prod_level = ClampU(i->prod_level + increment, PRODLEVEL_MINIMUM, PRODLEVEL_MAXIMUM);
|
||||
recalculate_multipliers = true;
|
||||
}
|
||||
}
|
||||
|
||||
/* Recalculate production_rate
|
||||
* For non-smooth economy these should always be synchronized with prod_level */
|
||||
if (recalculate_multipliers) {
|
||||
i->production_rate[0] = min(indspec->production_rate[0] * i->prod_level / PRODLEVEL_DEFAULT, 0xFF);
|
||||
i->production_rate[1] = min(indspec->production_rate[1] * i->prod_level / PRODLEVEL_DEFAULT, 0xFF);
|
||||
}
|
||||
|
||||
/* Close if needed and allowed */
|
||||
if (closeit && !CheckIndustryCloseDownProtection(i->type)) {
|
||||
i->prod_level = PRODLEVEL_CLOSURE;
|
||||
|
|
Loading…
Reference in New Issue